Installation •Operation •Maintenance Effective 5/8/2012
LITERATURE NUMBER
MPD 90307
Cold Weather Kit #90290
for On Demand Water Heater Models
OD4501 and OD5001
Cold Weather Kit Installation
1) Installation requires the disconnection of the
water lines, gas line, and electrical connections
in the rear of the unit and removal of the unit
from the RV to a bench.
2) First remove the upper tri-panel by removing
(25) screws, unplugging the pressure switch,
ignition control, relay and blower connection,
and lifting off the case, exposing the interior
components.
3)Next lay out the harness with the ground
eyelet at the grounding point with the existing
ground eyelet, the first and second ceramic at the
locations indicated, the pad behind the
modulation valve, and the thermostat close to the
inlet tube grommet.
Kit Includes:
- Heater Assembly # 90296
o Ceramic Clips (2)
o Heater assembly
o Tie Wraps (2 Long, 4 Short)
- Insulation Tape (36”) (Note: must be cut
into 16”, 14” and 4” pieces)
- Instruction
This kit includes the components necessary to
provide protection of the lower extremities of the
water circuit from freezing.
Protection of the heat exchanger (control of the
burner) is accomplished with a low temperature
thermostat which was provided standard on the
unit. It will provide protection for the heat
exchanger to ambient temperatures as low as 15°
F.
This kit is for adding protection of the lower
extremities i.e. the water tubes and the
modulation valve. It operates automatically
when the internal water temperature drops to
38°F.
Thermostat Replacement: (Part must be
ordered separately, # 90311)This switch is
used to light the burner for a limited ignition
cycle of the burner when temperatures dip to and
below approximately 40° F. It is only effective
when the power (12 vdc) is on and the LP tanks
are not turned off during travel or storage. If
there is continuity (switch closed) when the
ambient temperature is above 60° F, it is faulty
and requires replacement.